HomeMy WebLinkAboutKonica Monolta Drum (photoconductor) DR512-DR512KSAFETY DATA SHEET Page:4/7KONICAMINOLTANq>s Dpc_n22 Products Name:DRUM (PHOTOCONDUCTOR)DR512/DR512K Prepared Date:9-Jun-2011 Revised Date:25-May-2016 9.PHYSICAL AND CHEMICAL PROPERTIES Appearance Physical State:Solid Form:Cylinder Color Green Odc^Almost odorless «Results ofthecoatedcompounds onthealuminum substrate.» Boiling Point:Not applicable Melting/Softening Point:No data available FlashPoint Not applicable pH;Not applicable Explosion Properties:Not applicable Upper/lower flammability or explosive limits No data available DensityCg/cm3):1-2 Solubility in water insoluble Flammability:Not applicable Oxidizing Properties:No data available Auto-Ignition Temperature(0C):No data available Vapor Pressure:Not applicable Vapor density:Not applicable Partition Coefficient,n-Octanol/Waten Not applicable Decomposition temperature:Not applicable (*=Based on data for other Konica Minolta Products with similar ingredients) 10.STABILITY AND REACTIVITY Reactivity:None. Stability:Stable Hazardous Reactions:None Conditionsto avoid:None MaterialstoAvoid:None Hazardous Decomposition Products:CO,C02 SAFETY DATA SHEET Page:5/7 KONICA MINOLTA or^o M _1199SDSNo.:DPC-1122 Products Name:DRUM (PHOTOCONDUCTOR)DR512/DR512K Prepared Date:9-Jun-2011 Revised Date:25-May-2016 11.TOXICOLOGICAL INFORMATION Health Effects from Exposure:No symptoms expected with intended use. Toxicologic^ Data «Resultofthecoatedcompounds onthealuminum substrate.» Acute Toxicity: Inhalation,LC50(mg/l):Not applicable lngestion(oral),LD50(mg/kg):No data available Dermal,LD50(mg/kg):Not applicable Eye irritation:No data available Skin irritation:No data available Skin sensitizer Nodata available Mutagenicity:negative (AMES test) Local Effects:Nodata available ChronicToxicity orLong Term Toxicity:None Carcinogenicity IARC Monographs:Not listed NTP(USA):Not listed OSHARegulated(USA):Not listed 12.ECOLOGICAL INFORMATION No data available 13.DISPOSAL CONSIDERATION Appropriate Methods ofDisposalWastemaybedisposed or incinerated under conditions which meet all federal,state and local environmentalregulations. 14.TRANSPORT INFORMATION Special Precautions:None Information on Code and Classifications According to International Regulations UN Classification:None Further information:Not a dangerous good under IATA orIMDG. Hazchem code (Austl.):None KONICA MINOLTA SAFETY DATA SHEET Page:6/7 SDS No.:DPC-1122 Products Name:DRUM (PHOTOCONDUCTOR)DR512/DR512K Prepared Date:9-Jun-2011 Revised Date:25-May-2016 15.REGULATORY INFORMATION US Information California Proposition65: This product contains no chemical substances subject to California Proposition 65. CERCLA(Comprehensive Environmental Response Compensation and Liability Act): None.SARA Title III (Superfund Amendments and Reauthorization Act)302 Extreme Hazardous Substance : None. 311/312 Hazard Categories : None. 313 Reportable Ingredients : None. EU InformationThissafety datasheet complies with the requirements of Regulation (EC)No.1907/2006. •Regulation (EC)No 2037/2000 of the European Parliament and of the Council on Substances That Deplete theOzoneLayer:Not applicable•Regulation (EC)No 850/2004 of the European Parliament and of the Council on Persistent Organic Pollutants and Amending Directive 79/117/EEC (POPs):Not applicable•Regulation (EU)No 649/2012 of the European Parliament and of the Council on Concerning the Export and Import ofDangerous Chemicals (PIC):Not applicable •Directive 2012718/EU of the European Parliament and of the Council on the Control of Major-Accident Hazards Involving Dangerous Substances,Amending and Subsequently Repealing Council Directive 96/827EC,(Seveso III):Notapplicable •Regulation (EC)No 1907/2006 of the European Parliament and of the Council: -Annex XIV-List ofSubstances Subject ToAuthorization:Not applicable -Annex XVII-Restrictions on the Manufacture,Placing on the Market and Use of Certain Dangerous Substances,Preparations and Articles:Not applicable For this product a chemical safety assessment was not carried out. SAFETY DATA SHEET Page:7/7 KONICA MINOLTA SDS No.:DPC-1122 Products Name:DRUM (PHOTOCONDUCTOR)DR512/DR512K Prepared Date:9-Jun-2011 Revised Date:25-May-2016 16.OTHER INFORMATION NFPA Hazard Rating:TheNational Fire Protection Agency(USA):Health:0 Flammability:1 Reactivity:0 HMIS RATING:The National Paintand Coating Association(USA):Health:0 Flammability:1 Reactivity:0 Recommended Uses:Photoconductorfor ElectrophotographicEquipment Abbreviations: ACGIH-TWA:Threshold Limit Value ofAmerican Conference ofGovernment Industrial Hygienists CERCLA Comprehensive Environmental Response,Compensation,and Liability Act DFG-MAK:Maximale Arrjeitsplatz-Konzentration by Deutsche Forschuugsgemeinschaft DGR:Dangerous Goods Regulations EINECS:European Inventory of Existing Commercial Chemical Substances H-Code:Hazard Code HMIS:Hazardous Materials Identification System IARC:International AgencyforResearch onCancer IATA:InternationalAirTransport Association IMDG:International MaritimeDangerous Goods Code NTP: National Toxicology Program OEL:Occupational exposure limit OSHA:OccupationalSafetyand HealthAdministration PBT:Persistent,Bioaccumulative and Toxic SARA:Superfund Amendmentsand Reauthorization Act TSCA:Toxic Substances Control Act vPvB:veryPersistent and very Bioaccumulative Revision Information:Regular revisionon revised date. Literature References: ANSIZ400.1-1993 ISO 11014-1 Commission Directive 91/155/EEC Restrictions: The above information isbelievedto be accurate and represents the best information currently availableto Our Corporation.However,Our Corporation makes no warranty with respect tosuch information,and Our Corporation assumesno liability resulting from its use.Users should make their own investigation to determine the suitability ofthe information for their particular purposes.