HomeMy WebLinkAboutKonica Monolta Drum (photoconductor) DR512-DR512KSAFETY DATA SHEET Page:4/7KONICAMINOLTANq>s Dpc_n22
Products Name:DRUM (PHOTOCONDUCTOR)DR512/DR512K
Prepared Date:9-Jun-2011
Revised Date:25-May-2016
9.PHYSICAL AND CHEMICAL PROPERTIES
Appearance
Physical State:Solid Form:Cylinder Color Green
Odc^Almost odorless
«Results ofthecoatedcompounds onthealuminum substrate.»
Boiling Point:Not applicable
Melting/Softening Point:No data available
FlashPoint Not applicable
pH;Not applicable
Explosion Properties:Not applicable
Upper/lower flammability or explosive limits No data available
DensityCg/cm3):1-2
Solubility in water insoluble
Flammability:Not applicable
Oxidizing Properties:No data available
Auto-Ignition Temperature(0C):No data available
Vapor Pressure:Not applicable
Vapor density:Not applicable
Partition Coefficient,n-Octanol/Waten Not applicable
Decomposition temperature:Not applicable
(*=Based on data for other Konica Minolta Products with similar ingredients)
10.STABILITY AND REACTIVITY
Reactivity:None.
Stability:Stable
Hazardous Reactions:None
Conditionsto avoid:None
MaterialstoAvoid:None
Hazardous Decomposition Products:CO,C02
SAFETY DATA SHEET Page:5/7
KONICA MINOLTA or^o M _1199SDSNo.:DPC-1122
Products Name:DRUM (PHOTOCONDUCTOR)DR512/DR512K
Prepared Date:9-Jun-2011
Revised Date:25-May-2016
11.TOXICOLOGICAL INFORMATION
Health Effects from Exposure:No symptoms expected with intended use.
Toxicologic^ Data
«Resultofthecoatedcompounds onthealuminum substrate.»
Acute Toxicity:
Inhalation,LC50(mg/l):Not applicable
lngestion(oral),LD50(mg/kg):No data available
Dermal,LD50(mg/kg):Not applicable
Eye irritation:No data available
Skin irritation:No data available
Skin sensitizer Nodata available
Mutagenicity:negative (AMES test)
Local Effects:Nodata available
ChronicToxicity orLong Term Toxicity:None
Carcinogenicity
IARC Monographs:Not listed
NTP(USA):Not listed
OSHARegulated(USA):Not listed
12.ECOLOGICAL INFORMATION
No data available
13.DISPOSAL CONSIDERATION
Appropriate Methods ofDisposalWastemaybedisposed or incinerated under conditions which meet all federal,state and local
environmentalregulations.
14.TRANSPORT INFORMATION
Special Precautions:None
Information on Code and Classifications According to International Regulations
UN Classification:None
Further information:Not a dangerous good under IATA orIMDG.
Hazchem code (Austl.):None
KONICA MINOLTA
SAFETY DATA SHEET Page:6/7
SDS No.:DPC-1122
Products Name:DRUM (PHOTOCONDUCTOR)DR512/DR512K
Prepared Date:9-Jun-2011
Revised Date:25-May-2016
15.REGULATORY INFORMATION
US Information
California Proposition65:
This product contains no chemical substances subject to California Proposition 65.
CERCLA(Comprehensive Environmental Response Compensation and Liability Act):
None.SARA Title III (Superfund Amendments and Reauthorization Act)302 Extreme Hazardous Substance :
None.
311/312 Hazard Categories :
None.
313 Reportable Ingredients :
None.
EU InformationThissafety datasheet complies with the requirements of Regulation (EC)No.1907/2006.
•Regulation (EC)No 2037/2000 of the European Parliament and of the Council on Substances That
Deplete theOzoneLayer:Not applicable•Regulation (EC)No 850/2004 of the European Parliament and of the Council on Persistent Organic
Pollutants and Amending Directive 79/117/EEC (POPs):Not applicable•Regulation (EU)No 649/2012 of the European Parliament and of the Council on Concerning the Export
and Import ofDangerous Chemicals (PIC):Not applicable
•Directive 2012718/EU of the European Parliament and of the Council on the Control of Major-Accident
Hazards Involving Dangerous Substances,Amending and Subsequently Repealing Council Directive
96/827EC,(Seveso III):Notapplicable
•Regulation (EC)No 1907/2006 of the European Parliament and of the Council:
-Annex XIV-List ofSubstances Subject ToAuthorization:Not applicable
-Annex XVII-Restrictions on the Manufacture,Placing on the Market and Use of Certain
Dangerous Substances,Preparations and Articles:Not applicable
For this product a chemical safety assessment was not carried out.
SAFETY DATA SHEET Page:7/7
KONICA MINOLTA
SDS No.:DPC-1122
Products Name:DRUM (PHOTOCONDUCTOR)DR512/DR512K
Prepared Date:9-Jun-2011
Revised Date:25-May-2016
16.OTHER INFORMATION
NFPA Hazard Rating:TheNational Fire Protection Agency(USA):Health:0 Flammability:1 Reactivity:0
HMIS RATING:The National Paintand Coating Association(USA):Health:0 Flammability:1 Reactivity:0
Recommended Uses:Photoconductorfor ElectrophotographicEquipment
Abbreviations:
ACGIH-TWA:Threshold Limit Value ofAmerican Conference ofGovernment Industrial Hygienists
CERCLA Comprehensive Environmental Response,Compensation,and Liability Act
DFG-MAK:Maximale Arrjeitsplatz-Konzentration by Deutsche Forschuugsgemeinschaft
DGR:Dangerous Goods Regulations
EINECS:European Inventory of Existing Commercial Chemical Substances
H-Code:Hazard Code
HMIS:Hazardous Materials Identification System
IARC:International AgencyforResearch onCancer
IATA:InternationalAirTransport Association
IMDG:International MaritimeDangerous Goods Code
NTP: National Toxicology Program
OEL:Occupational exposure limit
OSHA:OccupationalSafetyand HealthAdministration
PBT:Persistent,Bioaccumulative and Toxic
SARA:Superfund Amendmentsand Reauthorization Act
TSCA:Toxic Substances Control Act
vPvB:veryPersistent and very Bioaccumulative
Revision Information:Regular revisionon revised date.
Literature References:
ANSIZ400.1-1993
ISO 11014-1
Commission Directive 91/155/EEC
Restrictions:
The above information isbelievedto be accurate and represents the best information currently availableto
Our Corporation.However,Our Corporation makes no warranty with respect tosuch information,and Our
Corporation assumesno liability resulting from its use.Users should make their own investigation to
determine the suitability ofthe information for their particular purposes.